Two Common Steam Temperatures

Captions available

The idea

Two steam-sterilizing temperatures are common: about two hundred fifty degrees Fahrenheit and about two hundred seventy degrees Fahrenheit.

In practice

A wrapped load needs about thirty minutes at the lower temperature in a gravity sterilizer, or about four minutes at the higher one in a prevacuum sterilizer.

Where people slip

Times also vary by item and wrapping, so follow the manufacturer's directions.